Kuhner shakers are suitable for the cultivation of microbial, plant, human and animal cell cultures. In the registers below you will find more information about the different application areas and suitable product recommendations for optimal cultivation.

Alternative application areas such as mixing or thawing can be found in the second section of this page.

Application: Organisms

Stem cells
Cell culture
Yeasts & Fungi
Bacteria
Plant cells & algae
Stem cells

Stem cell cultivations run for several days or weeks and normally requires specific cultivation conditions, such as a low oxygen concentration (1-8%), high carbon dioxide concentration (4-10%), and a high relative humidity (>70%). Stem cells are mostly adherent cultures and are very sensitive to shear stress. Orbital shaken bioreactors are ideally suited for stem cell cultivations since they have a low local power input, therefore, significantly reducing the mechanical shear stress on the cultivated stem cells.

Stammzellen

Recommendation of Kuhner:

For cultivations in vessels/bioreactors with < 3 liters filling volume

Shaker:

  • Incubator shaker with CO2-, O2-, and humidity control: LT-X.

Accessories:

T
T
T
T

For cultivations in vessels/bioreactors with > 4 liters filling volume

Shaker:

  • SB10-X: Orbital shaken bioreactor with single-use bags (filling volume 4- 12 liters).


More information:

Cell culture

Cultivations of animal or human cell cultures run for several days or a few weeks. Usually, for cultivations they require a high carbon dioxide concentration (4-10%) and a high relative humidity (>70%). Cell cultures grow adherent or in suspension. Moreover, temperature shifts from 37 °C to 32 °C are often conducted during cultivations. When cultivating at a high relative humidity, this requires active dehumidifying of the incubator air to prevent condensation at the door or walls of the incubator shaker. 

Zellen

Recommendation of Kuhner:

Cultivations in microtiter plates (MTPs)

Shaker:

Options:

  • EPFL-table: This table accepts up to five (different) holders. To shake microtiter plates on the EPFL-table, a Duetz cover clamp is used which can accept up to 4 MTPs. Each holder has its own clamp handle allowing a complete Duetz cover clamp with 4 MTPS to be easily taken out of the incubator shaker and put on a clean bench while the other MTPs on the EPFL-table keep on shaking. 

  • Automatization: There are two main features Kuhner provides to support the automation. Optionally, an automatic door (ISF1-Z/X), which is activated by pressing a button on the shaker incubator or by using a foot switch. The other feature is a fixed stop position of the shaker table (not for 3 mm shaking diameter) which is important especially for a liquid handling robot. 

Accessories:

  • For small shaking diameters (e.g. 3 mm) and high shaking frequencies (~1000 rpm): Duetz system for 96 well microtiter plates.
  • Trays for microtiter plates: Handles at the front of the tray open and close the special clamping mechanism allowing plates to be loaded and unloaded. Trays of different heights (22, 47 and 77mm) allow the stacking of up to four microtiter plates. The trays are available in three sizes and suitable for all types of plates (deep well, low well, 24, 48 and 96 well).

Add-ons:

More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivations in tubes

 Shaker:

Options:

  • EPFL-table: This table accepts up to five tube holders, each with a capacity of 24 x 50ml tubes. Each tube holder has its own clamp handle allowing it to be easily taken out of the incubator shaker and put on a clean bench while the other tubes keep on shaking.

Accessories:

  • Trays for centrifuge tubes: special trays which are available in two different sizes; with a capacity of 72 (3x24) 50 ml centrifuge tubes or 120 (5 x 24) 50 ml tubes.

Add-ons:


More Information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivation in shake flasks up to 500 ml

Shaker:

Optionen:

Accessories:

  • Fixation of shake flasks on shaking tray: Sticky strips for low shaking frequencies (< 200 rpm), fixed metal clamps  for high shaking frequencies (> 200 rpm). 

Add-ons:

  • Kuhner TOMprovides online measurements of the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and respiratory quotient (RQ) for up to 16 individual shake flasks in a Kuhner incubator. 

More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivation in shake flasks up to 5 liters

Shakers:

  • Shaker incubator with humidity and CO2 control (for larger flasks a humidity control is less significant since the influence of the evaporation rate decreases for larger filling volumes): ISF1-ZLT-XISF4-X.

Accessories:

  • Tray with pins : The tray allows parallel shaking of 7 x 3 L Corning Fernbach culture flasks, 7 x 5 L Corning flasks, or 7 x 5 L Thomson Optimum Growth flasks and is therefore ideally suited for cell cultures. Flasks are held in position by pins and are easily placed on the tray and removed just as quickly.


More Information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivation in vessels/bioreactors > 5 liters

Shaker:

  • SB10-X: Orbital shaken bioreactor with single-use bags (filling volume 3-12 liters).
  • SB50-X: Orbital shaken bioreactor with single-use bags (filling volume 15-50 liters) and cooling (as an option).

  • SB200-XOrbital shaken bioreactor with single-use bags (filling volume 50-200 liters) and cooling (as an option).

More information: 

Bioreaktor SB10-X
Bioreaktor SB50-X
Bioreaktor SB200-X
Yeasts & Fungi

Cultivations of yeasts and fungi run for approximately 3 to 5 days. Yeasts and fungi have a higher oxygen demand than animal or human cell cultures. A higher oxygen transfer can be achieved by decreasing the filling volume and increasing the shaking frequency. Moreover, active humidity control might be helpful to reduce evaporation losses. Filamentous fungi can increase the viscosity of the cultivation medium. In that case, large shaking diameters (50 or even 70 mm) should be chosen to prevent the occurrence of the “out-of-phase” phenomenon.

Hefen und Pilze

Recommendation of Kuhner:

Cultivations in microtiter plates (MTPs)

Shaker:

  • Increasing the shaking capacity: up to three ISF1-Z incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories (stacked incubator shakers can also be operated at high shaking frequencies). 

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to five individual shaking tables in one incubator chamber. 

Options:

  • EPFL-table: This table accepts up to five (different) holders. To shake microtiter plates on the EPFL-table, a Duetz cover clamp is used which can take up to 4 MTPs. Each holder has its own clamp handle allowing a complete Duetz cover clamp with 4 MTPS to be easily taken out of the incubator shaker and put on a clean bench while the other MTPs on the EPLF-table keep on shaking.
  • Automatization: There are two main features Kuhner provides to support the automation. Optionally, an automatic door (ISF1-Z/X), which is activated by pressing a button on the shaker incubator or by using a foot switch. The other feature is a fixed stop position of the shaker table (not for 3 mm shaking diameter) which is important especially for a liquid handling robot. 

Accessories:

  • For small shaking diameters (e.g. 3 mm) and high shaking frequencies (~1000 rpm): Duetz system for 96 well microtiter plates.

  • Trays for microtiter plates: Handles at the front of the tray open and close the special clamping mechanism allowing plates to be loaded and unloaded. Trays of different heights (22, 47 and 77mm) allow the stacking of up to four microtiter plates. The trays are available in three sizes and suitable for all types of plates (deep well, low well, 24, 48 and 96 well).

Add-ons:


More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivations in shake flasks up to 500 ml

Shaker:

  • Increasing the shaking capacity: up to three ISF1-Z/X incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories (stacked incubator shakers can also be operated at high shaking frequencies). 

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to five individual shaking tables in one incubator chamber. 

Accessories:

  • Fixation of shake flasks on shaking tray: fixed metalclamps for high shaking frequencies (> 200 rpm). 

Add-ons:

  • Kuhner TOM: provides online measurements of the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and respiratory quotient (RQ) for up to 16 individual shake flasks in a Kuhner incubator.

 

More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivation in shake flask up to 5 liters

Shaker:

  • Increasing the shaking capacity: up to three ISF1-Z incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories (stacked incubator shakers can also be operated at high shaking frequencies). 

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to five individual shaking tables in one incubator chamber. 

Accessories:

  • At lower shaking frequencies (< 200 rpm): tray with PC-plate for sticky strips -> the PC-plate increases the adhesion of the sticky strips. This is particularly helpful when using larger flasks > 500 ml.

  • At higher shaking frequencies (> 200 rpm): fixed  metal clamps/holders -> available for shake flasks with a nominal flask volume up to 6 L. 


More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X
Bacteria

Cultivations of bacteria run for several hours or days. Bacteria usually have a much higher oxygen demand than animal or human cell cultures and often also a higher oxygen demand than yeasts or fungi. A high oxygen transfer can be achieved by small filling volumes and high shaking frequencies (300-350 rpm). Moreover, a humidity control is helpful to prevent high evaporation losses (especially for very small filling volumes and cultivation temperatures of 30-37 °C). For very small filling volumes, large shaking diameters (50 or even 70 mm) should be chosen to prevent the occurrence of the “out-of-phase” phenomenon. 

Bakterien

Recommendation of Kuhner:

Cultivations in microtiter plates (MTPs)

Shaker:

  • Increasing the shaking capacity: up to three ISF1-Z incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories (stacked incubator shakers can also be operated at high shaking frequencies). 

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to five individual shaking tables in one incubator chamber. 

Options:

  • EPFL-table: This table accepts up to five (different) holders. To shake microtiter plates on the EPFL-table, a Duetz cover clamp is used which can take up to 4 MTPs. Each holder has its own clamp handle allowing a complete Duetz cover clamp with 4 MTPS to be easily taken out of the incubator shaker and put on a clean bench while the other MTPs on the EPLF-table keep on shaking.
  • Automatization: There are two main features Kuhner provides to support the automation. Optionally, an automatic door    (ISF1-Z/X), which is activated by pressing a button on the shaker incubator or by using a foot switch. The other feature is a fixed stop position of the shaker table (not for 3 mm shaking diameter) which is important especially for a liquid handling robot. 

Accessories:

  • For small shaking diameters (e.g. 3 mm) and high shaking frequencies (~1000 rpm): Duetz system for 96 well microtiter plates.

  • Trays for microtiter plates: Handles at the front of the tray open and close the special clamping mechanism allowing plates to be loaded and unloaded. Trays of different heights (22, 47 and 77mm) allow the stacking of up to four microtiter plates. The trays are available in three sizes and suitable for all types of plates (deep well, low well, 24, 48 and 96 well).



More informationen:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivations in shake flasks up to 500 ml

Shaker:

  • Increasing the shaking capacity: up to three ISF1-Z incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories (stacked incubator shakers can also be operated at high shaking frequencies). 

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to five individual shaking tables in one incubator chamber. 

Accessories:

  • Fixation of shake flasks on shaking tray: fixed metal clamps for high shaking frequencies (> 200 rpm). 

Add-ons: 

  • Kuhner TOM: provides online measurements of the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and respiratory quotient (RQ) for up to 16 individual shake flasks in a Kuhner incubator.

 

More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivations in shake flasks up to 5 liters

Shaker:

  • Increasing the shaking capacity: up to three ISF1-Z/X incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories (stacked incubator shakers can also be operated at high shaking frequencies). 

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to three individual shaking tables in one incubator chamber. 

Accessories:

  • At lower shaking frequencies (< 200 rpm): tray with PC-plate for sticky strips -> the PC-plate increases the adhesion of the sticky strips. This is particularly helpful when using larger flasks > 500 ml.
  • At higher shaking frequencies (> 200 rpm): metal clamps/holders  -> available for shake flasks with a nominal flask volume up to 6 L. 


More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X
Plant cells & algae

Cultivations of plant cell cultures and algae run for approximately 5 to 7 days. The oxygen demand lies in between animal cell cultures and bacteria. For longer cultivations, active humidity control is useful to decrease evaporation from the cultivation vessels. Many cultures require LED light for their photosynthesis reaction. Also, depending on the plant cell culture,  CO2 control might be necessary. 

Pflanzenzellen

Recommendation of Kuhner:

Cultivations in microtiter plates (MTPs)

Shaker with LED light module and CO2 control:

  • Incubator shaker with photosynthesis module (LED light module), humidity and CO2 control: LT-XISF4-X.
  • Increasing the shaking capacity: up to two LT-X incubator shakers can be easily stacked without any additional accessories.

Two options are available for integrating the LED light module:

  • LED light module in the inside of the incubator shaker.
  • LED light module above an incubator shaker (ISF1-Z) with a glass roof (for less heat buildup inside the incubator).

Shaker without LED light module and CO2 control:

  • Increasing the shaking capacity: up to three ISF1-Z incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories.

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to five individual shaking tables in one incubator chamber. 

Options:

  • EPFL-table: This table accepts up to five (different) holders. To shake microtiter plates on the EPFL-table, a Duetz cover clamp is used which can take up to 4 MTPs. Each holder has its own clamp handle allowing a complete Duetz cover clamp with 4 MTPS to be easily taken out of the incubator shaker and put on a clean bench while the other MTPs on the EPLF-table keep on shaking. 

  • Automatization: Optionally, an automatic door (ISF1-Z), which is activated by pressing a button on the incubator shaker or by using a foot switch, and a fixed stop position of the shaker tray (not for 3 mm shaking diameter) are available. A fixed stop position is especially useful for automated processes using a liquid handling robot. 

Accessories:

  • For small shaking diameters (e.g. 3 mm) and high shaking frequencies (~1000 rpm): Duetz system for 96 well microtiter plates.

  • Trays for microtiter plates: Handles at the front of the tray open and close the special clamping mechanism allowing plates to be loaded and unloaded. Trays of different heights (22, 47 and 77mm) allow the stacking of up to four microtiter plates. The trays are available in three sizes and suitable for all types of plates (deep well, low well, 24, 48 and 96 well).

Add-ons:

 

More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivations in shake flasks up to 500 ml

Shaker with LED light module and CO2 control:

  • Incubator shaker with photosynthesis module (LED light module), humidity and CO2 control: LT-XISF4-X.
  • Increasing the shaking capacity: up to two LT-X incubator shakers can be stacked.

Two options are available for integrating the LED light module:

  • LED light module in the inside of the incubator shaker.

  • LED light module above an incubator shaker (ISF1-Z/X) with a glass roof (for less heat buildup inside the incubator).

Shaker without LED light module and CO2 control:

  • Increasing the shaking capacity: up to three ISF1-Z incubator shakers or up to two LT-X incubator shakers can be stacked
  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to four individual shaking tables in one incubator. 

Options:

Accessories:

  • Fixation of shake flasks on shaking tray: Sticky strips for low shaking frequencies (< 200 rpm), fixed metal clamps for or high shaking frequencies (> 200 rpm). 

Add-ons:

  • Kuhner TOM: provides online measurements of the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and respiratory quotient (RQ) for up to 16 individual shake flasks in a Kuhner incubator.

 

More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivations in shake flasks up to 5 liters

Shaker with LED light module and CO2 control:

  • Incubator shaker with photosynthesis module (LED light module), humidity and CO2 control: LT-XISF4-X.
  • Increasing the shaking capacity: up to two LT-X incubator shakers can be stacked.

Two options are available for integrating the LED light module:

  • LED light module in the inside of the incubator shaker.

  • LED light module above an incubator shaker (ISF1-Z/X) with a glass roof (for less heat buildup inside the incubator).

Shaker without LED light module and CO2 control:

  • Increasing the shaking capacity: up to three ISF1-Z incubator shakers or up to two LT-X incubator shakers can be easily stacked without any additional accessories.

  • Increasing the shaking capacity for identical cultivation conditions: ISF4-X – it allows for up to five individual shaking tables in one incubator chamber. 

Accessories:

  • At lower shaking frequencies (< 200 rpm): tray with PC-plate for sticky strips -> the PC-plate increases the adhesion of the sticky strips. This is particularly helpful when using larger flasks > 500 ml.

  • At higher shaking frequencies (> 200 rpm): metal clamps/holders -> available for shake flasks with a nominal flask volume up to 6 L. 

 

More information:

Schüttelinkubator ISF1-Z
Schüttelinkubator LT-X
Schüttelinkubator ISF4-X

Cultivation in vessels/bioreactors > 5 liters

Shaker without LED light module and CO2 control:

  • SB10-X: Orbital shaken bioreactor with single-use bags (filling volume 4-12 liters).
  • SB50-XOrbital shaken bioreactor with single-use bags (filling volume 15-50 liters) and cooling (as an option).

  • SB200-XOrbital shaken bioreactor with single-use bags (filling volume 50-200 liters) and cooling (as an option).


More information:

Bioreaktor SB10-X
Bioreaktor SB50-X
Bioreaktor SB200-X

Alternative application area: 

Thawing
Mixing
Thawing

In many cases, different types of liquids must be thawed gently and evenly in a laboratory besides the cultivation of cell cultures and microorganisms. These liquids include for instance cultivation media, cell cultures, protein and enzyme solutions. 

Auftauen

Recommendation of Kuhner:

Thawing in microtiter plates (MTPs)

Shaker:

  • Incubator shaker for thawing with a temperature profile: ISF1-ZLT-XISF4-X.

Options:

  • EPFL-table: This table accepts up to five (different) holders. To shake microtiter plates on the EPFL-table, a Duetz cover clamp is used which can take up to 4 MTPs. Each holder has its own clamp handle allowing a complete Duetz cover clamp with 4 MTPS to be easily taken out of the incubator shaker and put on a clean bench while the other MTPs on the EPLF-table keep on shaking.
  • Kuhner Insight software: allows for the programming of specific thawing programs (e.g. with temperature profiles) -> also suitable for work in a GMP environment.

Accessories:

  • Trays for microtiter platesHandles at the front of the tray open and close the special clamping mechanism allowing plates to be loaded and unloaded. Trays of different heights (22, 47 and 77mm) allow the stacking of up to four microtiter plates. The trays are available in three sizes and suitable for all types of plates (deep well, low well, 24, 48 and 96 well).

Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X

Thawing in tubes

Shaker:

  • Incubator shaker for thawing with a temperature profile: ISF1-ZLT-XISF4-X.

Options:

  • EPFL-table: This table accepts up to five tube holders, each with a capacity of 24 x 50ml tubes. Each tube holder has its own clamp handle allowing it to be easily taken out of the incubator shaker and put on a clean bench while the other tubes keep on shaking.
  • Kuhner Insight software: allows for the programming of specific thawing programs (e.g. with temperature profiles) -> also suitable for work in a GMP environment.

Accessories:

  • Trays for centrifuge tubes: special trays which are available in two different sizes; with a capacity of 72 (3x24) 50 ml centrifuge tubes or 120 (5 x 24) 50 ml tubes.
Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X

Thawing in bags (e.g. blood or cryo bags)

Shaker:

  • Incubator shaker for thawing with a temperature profile: ISF1-ZLT-XISF4-X.

Options:

  • Kuhner Insight softwareallows for the programming of specific thawing programs (e.g. with temperature profiles) -> also suitable for work in a GMP environment.

Accessories:

  • 2D-Bag-tray (Cryo)tray for shaking (orbital or linear) 2D-Bags. Rubber bands secure smaller blood and cryo bags. It accepts various brands and sizes of pillow shaped single-use bags: 1 x 20 L (10 L working volume), 2 x 10 L (5 L working volume), 10 x 500 ml, or 12 x 250 ml.

  • 2D-Bag-tray (Flex): tray for shaking (orbital or linear) different types of 2D-bags. The tray consists of an aluminum base with a flexible mounting system on top. The mounting system can be manually adjusted to facilitate the controlled fixing of different sized cultivation bags. The mounting bars on both longitudinal sides can be moved up and down to hold the cultivation bag in place, while rubber bands will secure the smaller blood and cryo bags. The tray accepts various brands and sizes of pillow shaped single-use bags: 1 x 20 L (10 L working volume), 2 x 10 L (5 L working volume), 10 x 500 ml, or 12 x 250 ml.

Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X

Thawing in other vessels (e.g. bottles)

Shaker:

  • Incubator shaker for thawing with a temperature profile: ISF1-ZLT-XISF4-X.

Options:

  • Kuhner Insight softwareallows for the programming of specific thawing programs (e.g. with temperature profiles) -> also suitable for work in a GMP environment.

Accessories:

  • Tray with support barsThis tray offers an alternative to both clamps and sticky mats and are ideal for tall containers. The tray is covered with a rubber mat and has an upright at each corner. E and EX size trays are fitted with four cross supports while the F tray is equipped with six. These support bars support and securely clamp the containers.

Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X
Mixing

In many cases, different kinds of liquids must be mixed or shaken in a laboratory besides the cultivation of cell cultures and microorganisms. These liquids may include chemical substances, oils with particulate matter, liquid/crystalline mixtures, protein, enzyme solutions, blood bags, or solutions containing catalysts. 

Mischen

Recommendation of Kuhner:

Mixing in microtiter plates (MTPs)

Shaker:

Options:

  • EPFL-table: This table accepts up to five (different) holders. To shake microtiter plates on the EPFL-table, a Duetz cover clamp is used which can take up to 4 MTPs. Each holder has its own clamp handle allowing a complete Duetz cover clamp with 4 MTPS to be easily taken out of the incubator shaker and put on a clean bench while the other MTPs on the EPFL-table keep on shaking.

Accessories:

  • Trays for microtiter plates: Handles at the front of the tray open and close the special clamping mechanism allowing plates to be loaded and unloaded. Trays of different heights (22, 47 and 77mm) allow the stacking of up to four microtiter plates. The trays are available in three sizes and suitable for all types of plates (deep well, low well, 24, 48 and 96 well).

More information:

Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X

Mixing in tubes

Shaker:

Options:

  • EPFL-table: This table accepts up to five tube holders, each with a capacity of 24 x 50ml tubes. Each tube holder has its own clamp handle allowing it to be easily taken out of the incubator shaker and put on a clean bench while the other tubes keep on shaking. 

Accessories:

  • Trays for centrifuge tubes: special trays which are available in two different sizes; with a capacity of 72 (3x24) 50 ml centrifuge tubes or 120 (5 x 24) 50 ml tubes.

More information:

Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X

Mixing in bags (e.g. blood or cryo bags)

Shaker:

  • Incubator shaker for thawing with a temperature profile: ISF1-ZLT-XISF4-X.

Options:

Accessories:

  • 2D-Bag-tray (Cryo): tray for shaking (orbital or linear) 2D-Bags. Rubber bands secure smaller blood and cryo bags. It accepts various brands and sizes of pillow shaped single-use bags: 1 x 20 L (10 L working volume), 2 x 10 L (5 L working volume), 10 x 500 ml, or 12 x 250 ml.

  • 2D-Bag-tray (Flex): tray for shaking (orbital or linear) different types of 2D-bags. The tray consists of an aluminum base with a flexible mounting system on top. The mounting system can be manually adjusted to facilitate the controlled fixing of different sized cultivation bags. The mounting bars on both longitudinal sides can be moved up and down to hold the cultivation bag in place, while rubber bands will secure the smaller blood and cryo bags. The tray accepts various brands and sizes of pillow shaped single-use bags: 1 x 20 L (10 L working volume), 2 x 10 L (5 L working volume), 10 x 500 ml or 12 x 250 ml.

More information:

Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X

Mixing in other vessels (e.g. bottles, separating funnel)

Shaker:

  • Incubator shaker for thawing with a temperature profile: ISF1-ZLT-XISF4-X.

Accessories:

  • Tray with support bars: This tray offers an alternative to both clamps and sticky mats and are ideal for tall containers. The tray is covered with a rubber mat and has an upright at each corner. E and EX size trays are fitted with four cross supports while the F tray is equipped with six. These support bars support and securely clamp the containers.
  • Trays for separating vessels/funnels: special tray for shaking separating vessels. This very flexible tray can take vessels of various sizes. It is also possible to add a second layer and double the capacity. Movable retaining rods allow vessels to be installed easily.

More information:

Lab Shaker LS-Z
T
Schüttelinkubator ISF1-Z
Schüttelinkubator ISF4-X

«Kuhner respects your privacy»

We use cookies to provide you with an innovative experience on our website and to improve our communication with you. Cookies on this website are used to ① improve the user experience (strictly necessary Cookies) ② personalize information about your country and ③ learn how our website is used.

close x

Necessary for the usability of the website (always active)

Necessary cookies help to make a website usable by enabling basic functions such as page navigation and access to secure areas of the website. The website cannot function properly without these cookies.

Save country and language settings for convenience 

Country and language cookies allow our website to remember information such as: Your preferred language or country of residence. You will always receive the right information and valid offers tailored to your country.

Statistics for performance measurement 

Statistics cookies help us as a website operator to understand how visitors interact with websites by collecting and reporting information anonymously. From the statistics, we gain insights in order to constantly adapt the further development of our communication to the needs of the visitors.

Further information on the handling of cookies and information on data protection can be found here. You can adjust your cookie preferences in the settings.