The Kuhner LT-X (Lab-Therm) incubator shaker
has the same capabilities as the larger ISF1-Z and ISF4-X models. The incubator
shaker was specially developed to address the shaking needs of the
biotechnology and pharmaceutical industries. The practical size of the LT-X
means it will fit in any laboratory.
• Fits into any laboratory
• Used in biotech and pharmaceutical industries
•
Accepts flasks up to 6 litres
•
Two units can be stacked without the need for special kits or tools
• Humidity, CO2 and O2 control available

5-year warranty

CO2 control

O2 control

Humidity control
Exceptional chamber height means flasks up to 6 litres capacity can be accommodated. If using smaller flasks, there is sufficient head height to fit one or two stationary trays above the shaking table. It is also possible to stack two LT-X together without the need for special kits or tools.

The maintenance-free direct drive guarantees long and economical performance from the LT-X. The shaking diameter can be changed at any time thanks to Kuhner’s unique direct drive system. The integrated drive is protected from spills and the all stainless steel interior has a drain at the back for any unwanted liquids. The chamber can be cleaned using chemicals or sterilized with optional UV lighting.

A door switch ensures the motor stops as soon as the door is opened. After closing the door properly, the motor restarts. The safety, reliability and quality of our shakers are of personal concern to everyone at Kuhner which is why all our machines are supplied with a 5 year warranty.
We subject all our shaking machines to an elaborate final test before delivery. The detailed test protocols are available upon request.
At Kuhner, product quality and long service life are top priorities. This commitment has made Kuhner shakers and bioreactor systems trusted solutions in GMP-regulated environments worldwide. Documentation, development and manufacturing processes are continuously optimized throughout the entire product lifecycle to meet the evolving requirements of Good Manufacturing Practice (GMP).
The GMP version of our proprietary software, Kuhner Insight, enables precise control of shakers and bioreactors, seamless digital and analog communication with customer-specific infrastructure, and comprehensive storage, analysis and visualization of process recipes and data. These functionalities are designed to support compliance with FDA 21 CFR Part 11 and EU GMP Annex 11.
With the new Kuhner MPS-Z Automated, Kuhner expands its portfolio with an innovative solution for continuous, automated cell cultivation in microtiter plates. Featuring advanced interfaces and high process reliability, the MPS-Z Automated integrates seamlessly into existing automation platforms, supporting GMP-regulated workflows and clinical development processes.

The LT-X can be equipped with options for CO2, O2,controlled humidity, LED photosynthesis, UV lighting and much more. It is now also possible to integrate measuring data from Kuhner shakers with your company’s own network using Kuhner Insight software together with the NET-60 interface.

Dr. Shakers Helpful Hint N°4 explains what the shaking diameter is and how you can determine the shaking diameter of your lab shaker.
Find information on the importance of the shaking diameter for biological cultivations in our Shaking Technology Forum: Why is the shaking diameter important?

Whether you are developing therapeutics, advancing research, optimizing microbial production processes or supporting routine cultivation activities, the LT-X provides the precision, reliability and flexibility required to move forward with confidence. Discover why scientists and manufacturers around the world trust Kuhner.
Email our shaker team to discuss your specific laboratory project.
Find your local Kuhner expert to get in touch with our team in your country.

Find all the key specifications of the Kuhner LT-X at a glance, including dimensions, performance and available options. Use this data to compare configurations, check compatibility with your lab setup and prepare your purchase or qualification documents.

LT-X EcoDew® | LT-X Compressor |
108672 + 102011 | 108672 + 102008 |
LT-XC Basic | LT-XC EcoDew® | LT-XC Compressor |
108671 | 108671 + 102011 | 108671 + 102008 |
LT-X(C) Basic | LT-X(C) EcoDew® | LT-X(C) Compressor |
not available | included | 102010 |
LT-X(C) Basic | LT-X(C) EcoDew® | LT-X(C) Compressor |
102012 | 102012 | 102012 |
LT-X(C) Basic | LT-X(C) EcoDew® | LT-X(C) Compressor | |
Cooling | no | no | yes |
Humidity control | no | yes | no / yes |
Temperatur minimal | ambient + 10 °C | ambient
+ 10 °C | ambient – 15 °C (– 10 °C)* |
Temperatur maximal | 80°C (60°C)* | 80°C (60°C)* | 80°C (60°C)* |
Humidity maximal | - | 85 % r.h. | - / 85 % r.h. |
Power consumption | < 700W | < 1050W | < 880W / < 1150W |
* Shaking incubator optimized for cell cultures Technical changes reserved | |||
Gas volume | 260 l |
Weight (with cooling) | 170 kg |
Illumination | LED |
Operating menu in | German, French, English, Italian, Spanish |
Interface, standard | CAN-Bus |
Interface, optional | USB, Ethernet, digital, analogue |
Ambient temperature | 10°C up to 35°C |
Left sidewall
Cable feedthrough: PG 16 (ID 20mm)
Optional: 2nd cable feedthrough
Setting, digital | 0.1°C |
Accuracy, absolute |
± 0.30°C (37°C) ± 0.25°C (37°C)* |
Principle of sensor | Pt-100 |
Power of heating | 500 W |
Power of cooling | 90...155 W |
Air circulation | 160 m3/h |
max. at 25..55°C | 85% r.h. |
Setting, digital | 1% r.h. |
Accuracy, absolute | ± 2% r.h. |
Principle of sensor | capacitive |
Water refill | automatic |
Water heater | 180 W |
Door heater | 90 W |
Principle of sensor | Infrared, NDIR |
Measuring range | 0...20% CO2 |
Setting, digital | 0.1% |
|
Accuracy, absolute (including non-linearity, calibration uncertainty, repeatability) | ± 0.40% at 5% CO2 |
Temperature range | 5...60°C |
CO2-supply | max. 2 bar overpressure |
O2 sensor | zirconium oxide |
Measuring range | approximately 0% up
to ambient O2 (20.95% at dry air) |
Accuracy, absolute | ±0.40% at 5% O2 |
O2 sensor stability | ±0.5% full scale/year |
Setting, digital | ± 0.1% |
O2 control | PID, digital |
Temperature range | -10...80°C |
N2-supply | max. 0.5...0.8 bar overpressure |
110 - 120 V / 50-60 Hz | |
95 - 105 V / 50-60 Hz |
Tray size | EX (500 x 420mm) |
Loading, maximum | 25kg |
Setting, digital | 1 rpm |
Accuracy, absolute | ≤ 800 rpm = ± 0.5 rpm |
Timer | 1s ... 999h |
Acceleration | controlled |
Active brake | adjustable |
Stop on position | adjustable |
Speed | |
* orbital, Ø 12.5mm | 20...500 rpm |
* orbital, Ø 25.0mm | 20...400 rpm |
* orbital, Ø 50.0mm | 20...300 rpm |
* linear, ↔ 12.5mm | 20...400 rpm |
* linear, ↔ 25.0mm | 20...300 rpm |
* linear, ↔ 50.0 mm | 20…200 rpm |
* can be changed | |
Technical data subject to change
Extend the Kuhner LT-X with options that match your application. Add functions such as online monitoring, gas and humidity control or qualification documentation, and upgrade your system as your projects evolve. Our team is happy to help you choose the right configuration.

Overview Options
Temperature, humidity and gas control
Hygiene, cleaning and GMP compliance
Shaking capacity and loading
Light control for light-dependent and light-sensitive cultures
Comfort and safe handling
Monitoring and data
CO2 control is essential when working with mammalian cell cultures. Kuhner was the first company to manufacture and supply incubator shakers with CO2 control more than 15 years ago and continues to offer this option.
Learn more about Kuhner’s CO₂ control system.

A reliable control of O2 is essential for cultivating cells (proliferation and metabolism of stem cells) and microorganisms with low/no oxygen demand. The O2 controller reduces the O2 level from ambient (20.95% at dry air; normoxia) to approximately 0% O2 (hypoxic). A digital PID controller adjusts the N2 flow rate to maintain the desired O2 value.
Visit our poster gallery and find more information on the poster "Oxygen Transport Phenomena in Single-Use Shaking Flasks under Reduced Oxygen Conditions".pdf

All Kuhner incubator shakers can be fitted with cooling. The refrigeration system is regulated by a fully digital PID control ensuring minimal energy consumption. The cooling is switched on only when required as determined by the chamber temperature and set point.
Learn more about the temperature control.

Humidity control is an important factor in successful fermentation. Evaporation from microtiter plates, or when cultivating in flasks for long periods (e.g. cell cultures), can be significantly reduced with humidification.
To reduce evaporation from shake flasks or microtiter plates a water bath is placed inside the incubator. This water bath is fitted with an automatic water supply.
Our newly developed EcoDew®-Technology provides precise humidity control.

AerationSystem and FlowCon provide the ideal system for carrying out cell/stem cell cultivations in a simple, fast, and inexpensive manner.
Lab shakers in temperature-controlled rooms and incubator shakers without humidity and CO2-control can be equipped with the AerationSystem and FlowCon to easily implement humidification and a controlled gas composition for carrying out cell cultivations (e.g., CHO, HEK cells…) in shake flasks.

The LT-X is completely made of stainless steel. It can either be painted white or have a processed stainless steel look.

As in a biological safety cabinet, the chamber of a Kuhner incubator shaker can also be sterilized with an integrated UV lamp. The lamp is situated to maximise irradiation of the chamber and shaking table. The UV lamp has a clearly marked external switch and when the door is opened, the UV-lighting is automatically switched off.

IQ-OQ (Installation Qualification and Operation Qualification) is an equipment qualification according to GMP procedure. Kuhner offers this service which can also be carried out at the customer’s premises.

The dual table is an easy and economical way of doubling the shaking capacity. The dual shaking table consists of two levels. Each level will accept an E (420 x 420 mm) or EX (500 x 420 mm) size tray.
The dual table is available with a fixed distance between the two levels of either 120, 160, 180, or 200 mm. At the maximal distance of 200 mm the lower level accepts 125 mL, 250 mL, and 500 mL Erlenmeyer shake flasks.
However, with the dual table the shaking speed is limited to 200 rpm at a shaking diameter of 50 mm (all other maximum shaking frequencies, dependent on the shaking diameter, can be withdrawn from the LT-X manual).

The Kuhner EPFL-table offers maximum flexibility for screening and cultivation with different vessel types. Its individual clamps allow holders and universal trays to be quickly exchanged while the remaining vessels continue shaking. Compatible with microtiter plates, 50 mL centrifuge tubes, Erlenmeyer flasks, laboratory bottles and other cultivation vessels, the EPFL-table can be easily adapted to changing applications. Universal trays can also be equipped with sticky strips for flexible positioning of vessels of different sizes and shapes.
EPFL-tables are available for different Kuhner shaker models with 3, 4 or 5 individual clamps.

EPFL-table

EPFL-table with different holders

F-size tray clamped on the EPFL-table

Clamp handle
The ceiling of any Kuhner incubator shaker can be fitted with LED modules for the cultivation of phototrophic organisms. The control module allows full programming of night/day cycles and variable light intensity.

Available for light sensitive medium or organisms. Any Kuhner incubator shaker can be delivered with blackened windows to prevent unwanted daylight or UV radiation inside the incubator.
Check out the Kuhner EquipNote "Light protection for Kuhner incubators".

Kuhner has designed a new light shade plate for the LT-X. This plate is easily placed in front of the door window and held in position with clamps. It prevents radiation affecting the contents of the incubator chamber and protects light sensitive media from UV, artificial and/or daylight.
Simply lift the light shade plate to look at the cultures without opening the incubator door. When light protection is no longer required, the plate is easily removed.
Check out the Kuhner EquipNote "Light protection for Kuhner incubators".

To prevent accidental operation of the controllers, the panel can be protected by a perspex cover.

The TabCom option from Kuhner consists of a cable for power and data with the connection port integrated in the shaking table (see picture below). A cable guide prevents the cable breaking and ensures secure data recording. The flexibility of TabCom means online measurement systems can be easily integrated.

This option includes a 10.1-inch touchscreen with our Kuhner Insight Software. The touchscreen has been designed for simple operation, monitoring and programming. It can also be retrofitted to existing incubator shakers.
Learn more about our Display.

Kuhner TOM (Transfer-Rate Online Measurement) measures online oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR) and the respiratory quotient (RQ) in up to 16 individual shake flasks for better process understanding and informed process development. TOM is easily installed in any Kuhner shaker and can be operated with various flask types and sizes including single use shake flasks. Kuhner TOM has zero footprint on the shaker tray as it is mounted above (see picture below).

Adapt the Kuhner LT-X to your vessels and workflow with a wide range of accessories. Choose the right trays, clamps and adapters for your flasks, tubes and plates, and make the most of your bench space. All accessories are designed by Kuhner to fit your system and to be changed quickly as your experiments change.

Overview Accessories
Trays and clamps for shake flasks
Trays for microtiter plates
Trays for bags, tall and special vessels
More capacity, less bench space
Humidity and light protection
Software and connectivity
The universal tray can be fitted with clamps for Erlenmeyer flasks, test tube holders, microtiter plates, or custom made holders to suit your requirements.
Rearranging these clamps and holders is quick and simple.
Order number | Description |
|---|---|
102201 | Universal tray EU (420 x 420 mm) |
102207 | Universal tray EXU (500 x 420 mm) |

The clamps are riveted onto these trays and cannot be removed. They offer maximum stability and will often hold a larger number of flasks than universal trays. These trays are available in a variety of flask clamp sizes from 25 to 6000ml.
Ordner number | Description | Number of clamps |
|---|---|---|
101525 | E-25 ml | 81 |
101526 | E-50 ml | 50 |
101527 | E-100 ml | 39 |
101528 | E-125 ml | 30 |
101529 | E-150 ml | 30 |
101530 | E-200 ml | 20 |
101531 | E-250 ml | 18 |
101532 | E-300 ml | 15 |
101533 | E-500 ml | 12 |
101534 | E-1000 ml | 9 |
101535 | E-1500 ml | 5 |
101536 | E-2000 ml | 5 |
101537 | E-3000 ml | 4 |
101538 | E-4000 ml | 2 |
101539 | E-5000 ml | 2 |
101540 | E-6000 ml | 1 |
Order number | Description | Number of clamps |
|---|---|---|
101541 | EX-25 ml | 90 |
101542 | EX-50 ml | 60 |
101543 | EX-100 ml | 42 |
101544 | EX-125 ml | 36 |
101545 | EX-150 ml | 32 |
101546 | EX-200 ml | 25 |
101547 | EX-250 ml | 21 |
101548 | EX-300 ml | 18 |
101549 | EX-500 ml | 14 |
101550 | EX-1000 ml | 9 |
101551 | EX-1500 ml | 8 |
101552 | EX-2000 ml | 5 |
101553 | EX-3000 ml | 4 |
101554 | EX-4000 ml | 3 |
101555 | EX-5000 ml | 3 |
101556 | EX-6000 ml | 2 |

A tray fitted with sticky strips is especially useful for flasks shaken at low speeds (up to 200 rpm). The flask is placed directly on the sticky strip without the need for any other support. Flasks of all sizes can be used. Sticky strips are available individually or in sets and can also be supplied already fitted to a tray. The EX-size tray accepts five strips.
Order number | Description |
|---|---|
105169 | E-tray with 4 sticky strips (clear) |
105199 | EX-tray with 5 sticky strips (clear) |
105194 | 1 sticky strip: 385 x 85 x 3 mm (clear) |

The PC-plate increases the adhesion of the sticky strips. This is particularly helpful if using flasks >500ml.
Order number | Description |
|---|---|
105224 | EX-tray with 5 sticky strips (clear) |
105194 | 1 sticky strip: 385 x 85 x 3 mm (clear) |
105196 | 1 big sticky strip: 395 x 385 x 3 mm (clear) |

The pin-clamps are ideal for cleanrooms and areas where sticky mats or other standard clamps are not suitable. The clamps have been designed for easy cleaning and efficient handling of samples. The stainless-steel pin-clamps are compatible with all Kuhner universal trays. The shaking speed is limited to a maximum of 180 rpm at 50 mm shaking diameter.
| Order number | Description |
|---|---|
| 107167 | Pin-clamp 1000 mL Schott bottle/ 500 mL Erlenmeyer flask |
| 107168 | Pin-clamp 500 mL Schott bottle |
| 107324 | Pin-clamp 250 mL Erlenmeyer flask |
| 107326 | Pin-clamp 125 mL Erlenmeyer flask |
| 108729 | Pin-clamp 1000 mL Erlenmeyer flask |
| 108730 | Pin-clamp 1000 mL Duran / Kuhner TOM |
| 108731 | Pin-clamp 1600 mL Thomson Optimum Growth |
| 108732 | Pin-clamp 2800 mL Thomson Optimum Growth |
| 108733 | Pin-clamp 2000 mL Erlenmeyer flask |
| 108734 | Pin-clamp 3000 mL/ 5000 mL Fernbach flask / Corning & Thomson Optimum Growth |

Kuhner has designed trays specifically for microtiter plates. Handles at the front of the tray open and close the special clamping mechanism allowing plates to be loaded and unloaded. Trays of different heights (22, 47 and 77mm) allow the stacking of up to four microtiter plates. The trays are available in three sizes and suitable for all types of plates (deep well, low well, 24, 48 and 96 well).
Order number | Description | Numbers of clamps |
|---|---|---|
104947 | E-MT.22 | 12 to 24 |
104950 | E-MT.47 | 12 to 48 |
104948 | E-MT.77 | 12 to 72 |

Kuhner has designed a new tray for microtiter plates. This tray is fitted with springs which allows each well plate to be loaded and unloaded individually. The tray is available in three sizes: E (420x420mm), EX (500x420mm) and F (800x420mm).
This new tray is particularly suitable for the special holder with filter lid for deep well microtiter plates.
Order number | Description | Number of mircotiter plates |
|---|---|---|
104806 | E-tray(420 x 420 mm) for deepwell or mircrotiter plates | 1-12 |
104794 | EX-tray (500 x 420 mm) for deepwell or mircotiter plates | 1-15 |

The whole tray is covered with a rubber mat and is particularly suitable for shaking containers at low speed (e.g. blood bags).
Order number | Description |
|---|---|
105312 | Rubber mat EG |
105313 | Rubber mat EXG |

Kuhner has also designed a special tray for shaking separating vessels. This very flexible tray can take vessels of various sizes. It is also possible to add a second layer and double the capacity. Movable retaining rods allow vessels to be installed easily.
Order number | Description | Number of separating vessels |
|---|---|---|
SM420250 | ES-250 | 5 |
SM4202502 | ES-250/2 | 10 (2 layers) |
SM420500 | ES-500 | 4 |
SM4205002 | ES-500/2 | 8 (2 layers) |
SM421000 | ES-1000 | 3 |
SM4210002 | ES-1000/2 | 6 (2 layers) |

These trays offer an alternative to both clamps and sticky mats and are ideal for tall containers. The tray is covered with a rubber mat and has an upright at each corner. The EX size tray is fitted with four cross supports. These support bars securely clamp containers.
Order number | Description | Number of longitudinal girders |
|---|---|---|
106408 | EA-tray with rubber mat and 4 cross supports | 2 |
106407 | EXA- tray with rubber mat and 4 cross supports | 2 |

The dual tray offers two shaking levels and doubles the capacity. It is available in EXU, EX, FU and F size and the upper tray can be removed.
Please note the shaking speed is limited.
Order number | Description |
|---|---|
100548 | two EXU trays with 200mm distance (with holes) |
102226 | two EX trays with 200mm distance |

This stacking adapter is designed for stacking a LT-X on an ISF1-X/Z incubator shaker. Extra work space on the adapter allows room for flasks or a small machine, as well as the LT-X, thus creating a greater working area.
Order number | Description |
|---|---|
105864 | Stacking adapter (LT-X on ISF1-X/Z) |

For a comfortable working height Kuhner offers floor stands for both the ISF1-Z and LT-X incubator shakers. These are available in a choice of 400mm (2 x LT-X) or 765mm (1 x LT-X) high.
Floor stands with wheels are available for both the ISF1-Z and LT-X incubator shakers. These stands enable the user to move the machines easily. However, the shaking speed is limited.
Order number | Description |
|---|---|
100834 | 400mm high for 2 x LT-X |
100838 | 765mm high for 1 x LT-X |

Order number | Description |
|---|---|
100842 | 400mm high for 2 x LT-X |
100841 | 765mm high for 1 x LT-X |
105008 | Upgrade costs for castors (Polyamid)* |
*only for new machines | |



The Kuhner LT-X incubator shaker can be fitted with a shelf allowing cultivation in petri dishes. One or two shelves can be placed above the shaking table and fixed to the chamber walls with four screws.
Order number | Description |
|---|---|
102017 | Shelf for LT-X |

To reduce evaporation from shake flasks or microtitre plates a stainless steel water bath can be placed inside the incubator. This water bath is not fitted with an automatic water supply and must be topped up manually.
Order number | Description |
|---|---|
100799 | Humidity bath, coated, for LT-X |
110030 | Water supply kit for LT-X |
110025 | For a double stack: |
110025 | For a triple stack: |

Kuhner has designed a new light shade plate for the LT-X. This plate is easily placed in front of the door window and held in position with clamps. It prevents radiation affecting the contents of the incubator chamber and protects light sensitive media from UV, artificial and/or daylight.
Simply lift the light shade plate to look at the cultures without opening the incubator door. When light protection is no longer required, the plate is easily removed.
Check out the Kuhner EquipNote "Light protection for Kuhner incubators".
Order number | Description |
|---|---|
100855 | Light shade plate for LT-X |

The user-friendly Kuhner Insight software was developed for supervision, monitoring, and recording of data. The software is easy to operate.
Learn more about our Kuhner Insight.

Kuhner shakers are equipped with a CAN-bus. CAN-USB, CAN-Ethernet, EMI-60 and NET-60 are all well established interfaces.
Kuhner Shaker products are developed with and for scientists. Explore how our shaking technology performs in real laboratory and bioprocess applications, from cell culture to microbial fermentation.
Read Kuhner Notes for practical application insights, download Posters presenting results from our customers and partners, and visit the Science Room to dive deeper into shaking technology and bioprocess development.

Monitoring of pH and OTR using a multiple shake flask platform
Characterization of Algal Cell Culture in Photobioreactors
Oxygen Transport Phenomena in Single-Use Shaking Flasks
In our Science Room, we provide general information and data on cultivation processes in Shaken bioreactors.
Everything you need to know about the LT-X incubator shaker: space, load, maintenance, temperature, monitoring and upgrades.

The Kuhner LT-X (Lab-Therm) is a space-saving, stackable incubator shaker for biotechnology and pharmaceutical laboratories. It offers the same capabilities as the larger ISF1-Z and ISF4-X models in a size that fits any lab, accepts flasks up to 6 litres and can be equipped with humidity, CO₂ and O₂ control.
Kuhner shakers are suitable for the cultivation of microbial, plant, human and animal cell cultures. Typical applications of the LT-X are bacteria, cell culture, stem cells, plant cells and algae, supported by optional CO₂, O₂ and humidity control and LED illumination.
The exceptional chamber height of the LT-X accepts flasks up to 6 litres. An EX-tray (500 x 420 mm) has space for two 6-litre Erlenmeyer flasks. With smaller flasks there is enough head height for one or two stationary trays above the shaking table. Trays with fixed clamps are available for flask sizes from 25 mL to 6,000 mL.
Two LT-X units can be stacked without special kits or tools; stacking three is not possible. An LT-X can also be stacked on an ISF1-X/Z incubator shaker using a special stacking adapter. Floor stands are available at 400 mm (for two LT-X) and 765 mm (for one LT-X).
Yes, linear shaking is available besides orbital shaking. Orbital speeds are 20–500 rpm at a shaking diameter of 12.5 mm, 20–400 rpm at 25 mm and 20–300 rpm at 50 mm. Linear speeds are 20–400 rpm at 12.5 mm, 20–300 rpm at 25 mm and 20–200 rpm at 50 mm. Thanks to the direct drive, the shaking diameter can be changed at any time.
|
The dual table adds a second shaking level and doubles the capacity. The levels are fixed at 120, 160, 180 or 200 mm, and the shaking speed is limited to 200 rpm at a 50 mm shaking diameter. The EPFL-table with 3 clamps lets you combine different holders, for example for 50 mL tubes or microtiter plates, and remove a single holder while the others keep shaking.
The Basic and EcoDew® versions work from ambient +10 °C up to 80 °C; the Compressor version cools down to ambient −15 °C. Versions optimized for cell cultures cover ambient −10 °C (Compressor) to 60 °C. Temperature is set in 0.1 °C steps with an absolute accuracy of ± 0.30 °C at 37 °C (± 0.25 °C for cell culture versions).
Yes. The LT-XC models are optimized for cell culture and include CO₂ control with an infrared (NDIR) sensor for 0–20 % CO₂, with an absolute accuracy of ± 0.40 % at 5 % CO₂. Kuhner was the first company to supply incubator shakers with CO₂ control, more than 15 years ago.
Yes. The optional O₂ control (PhysOx control) lowers the oxygen level from ambient (20.95 % in dry air, normoxia) to approximately 0 % O₂ (hypoxic). A digital PID controller adjusts the N₂ flow to hold the set value, and the zirconium oxide sensor has an absolute accuracy of ± 0.40 % at 5 % O₂. It suits stem cells and microorganisms with low or no oxygen demand.
A door switch stops the motor as soon as the door is opened, and the motor restarts after the door is closed properly. The maintenance-free direct drive is protected from spills, and the all-stainless-steel interior has a drain at the back. The chamber can be cleaned with chemicals or sterilized with the optional UV lamp. All Kuhner shakers come with a 5 year warranty.
Yes, the LT-X can be used in the GMP sector. IQ-OQ documentation (Installation Qualification and Operation Qualification) is available and can also be carried out at your premises. Kuhner develops and produces its shakers according to 21 CFR and GAMP 5, and every machine undergoes a final test before delivery; the test protocol is sent to the customer.
Kuhner shakers have a CAN-bus interface as standard; USB, Ethernet, digital and analogue interfaces are optional. With Kuhner Insight software and the NET-60 interface, measuring data can be integrated into your company network. An optional 7-inch touchscreen with Kuhner Insight software enables operation, monitoring and programming and can be retrofitted to existing incubator shakers.
Get all the key information about the Kuhner LT-X in one document.
Our brochure gives you an overview of the main features, technical specifications and available options, so you can review, compare and share with your team at any time.

Kuhner shakers are suitable for the cultivation of microbial, plant, human and animal cell cultures. Find more information about the different application areas and suitable product recommendations for optimal cultivation here.




Adolf Kühner AG (Headquarters)
Dinkelbergstrasse 1
CH-4127 Birsfelden (Basel)
Switzerland
We support our customers in implementation, maintenance and repair of all Kuhner products – efficiently and competently.
For Kuhner, the quality and durability of their shakers and bioreactors have always been the topics with the highest priority. On this account, Kuhner products have also proven their worth worldwide under GMP requirements. Documentation, development and production along the full life cycle of our products are continuously enhanced to match the requirements of 21 CFR and GAMP 5.
Read more

The world's most reliable shaking machines built in-house in Switzerland.